Electron microscopy has allowed scientists to see individual atoms, but even at that resolution, not everything is clear.
The lenses of electron microscopes have intrinsic imperfections known as aberrations, and special aberration correctors – “like eyeglasses for your microscope,” said David Muller, the Samuel B. Eckert Professor of Engineering in the Department of Applied and Engineering Physics (AEP) – have been developed over the years to correct these defects.
Aberration correctors only go so far, however, and to correct multiple aberrations, you need an ever-expanding collector of corrector elements. It’s like putting glasses on glasses on glasses – it becomes a bit unwieldy.
Muller – along with Sol Gruner, the John L. Wetherill Professor of Physics, and Veit Elser, professor of physics – have developed a method for achieving ultra-high resolution without the need for “corrective lenses” for their microscope.
They’ve employed their Cornell-developed electron microscope pixel array detector (EMPAD), which was introduced in March 2017. With it they’ve achieved what Muller, co-director of the Kavli Institute at Cornell for Nanoscale Science, said is a world record for image resolution – in this case using monolayer (one-atom-thick) molybdenum disulfide (MoS2).
Their achievement is reported in “Electron Ptychography of 2-D Materials to Deep Sub-Ångström Resolution,” to be published July 19 in Nature. Co-lead authors were Yi Jiang, Ph.D. ’18 (physics) and Zhen Chen, a postdoctoral researcher in the Muller Group.
Electron wavelengths are many times smaller than those of visible light, but electron microscope lenses are not commensurately precise.
Typically, Muller said, the resolution of an electron microscope is dependent in large part on the numerical aperture of the lens. In a basic camera, the numerical aperture is the reciprocal of the “f-number” – the smaller the number, the better the resolution.
In a good camera, the lowest f-number or “f-stop” might be a little under 2, but “an electron microscope has an f-number of about 100,” Muller said. Aberration correctors can bring that number down to about 40, he said – still not great.
Image resolution in electron microscopy has traditionally been improved by increasing both the numerical aperture of the lens and the energy of the electron beam, which does for the microscope what light does for a camera or an optical microscope – illuminates the subject.
Read more: Electron microscope detector achieves record resolution
thumbnail courtesy of phys.org